English Chinese Simplified Chinese Traditional French German Portuguese Spanish Russian Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Contact
Leave Your Message

Brazil ANATEL Lithium Battery Safety Compliance: What Stationary Battery Manufacturers Need to Know for 2026

2026-08-10

TL;DR — Key Takeaways for Stationary Lithium Battery Exporters

  • ANATEL Resolution No. 715/2019 governs mandatory product certification for telecommunications and electronic equipment in Brazil, including stationary lithium battery systems used in telecom base stations and UPS infrastructure.
  • IEC 62619:2022 is the primary safety standard for secondary lithium cells and batteries in industrial applications — stationary energy storage systems fall squarely within its scope.
  • Brazil requires certification through designated conformity assessment bodies (OCDs) before ANATEL homologation is granted, meaning third-party lab testing is not optional.
  • Thermal runaway propagation testing, overcharge protection, and external short-circuit tests are among the critical safety evaluations manufacturers must pass.
  • Our testing team at RTS has guided dozens of battery manufacturers through multi-market certification, and we’ve compiled this guide to help you navigate Brazil’s evolving stationary battery requirements ahead of the 2026 compliance deadline.

When our team first started receiving inquiries from stationary lithium battery manufacturers about Brazil’s ANATEL certification requirements, our most frequently asked question was straightforward: “Do we really need ANATEL approval to sell battery systems into Brazil?” The answer, backed by ANATEL’s own regulatory framework, is an unequivocal yes — and our compliance landscape is becoming more rigorous as Brazil scales its telecommunications and energy infrastructure.

For manufacturers exporting stationary lithium batteries — the kind used in telecom base stations, uninterruptible power supply (UPS) systems, and renewable energy storage — understanding Brazil’s certification pathway is not just a regulatory checkbox. It is a market access gate that determines whether your product can legally be sold, installed, and operated in one of Latin America’s largest economies.

In this guide, our team walks you through our regulatory framework, our specific testing standards that apply, and our practical steps our clients take to achieve ANATEL homologation for stationary lithium battery products.

Our compliance consultants have spent years studying our regulatory landscape that governs battery exports to Latin America.

Understanding Brazil’s ANATEL Certification Framework

ANATEL (Agência Nacional de Telecomunicações) is Brazil’s national telecommunications agency, and it administers a compulsory certification program for products that connect to or support telecom infrastructure. Our compliance consultants have deep experience with this framework, and we can confirm that our applicable regulation remains ANATEL Resolution No. 715 of October 23, 2019, which establishes the conformity assessment requirements for telecommunications products.

Under Resolution 715/2019, products within ANATEL’s scope — including backup battery systems for telecom infrastructure — must undergo certification by a designated conformity assessment body (OCD, or Organismo de Certificação Designado) before they can receive ANATEL homologation. The OCD evaluates our product against applicable technical requirements, and our resulting conformity certificate is a mandatory prerequisite for homologation.

Because stationary lithium batteries serve as critical backup power for telecom base stations and network infrastructure, they fall within ANATEL’s regulatory jurisdiction. This means that even if your battery product has already passed IEC or UL testing for other markets, you still need ANATEL-specific certification to legally deploy it in Brazil.

What is ANATEL Homologation? Homologation is the formal authorization ANATEL grants after a product has been certified by an OCD. Without homologation, a product cannot be legally commercialized or operated in Brazil. The process requires test reports from accredited labs, product documentation, and compliance declarations.

Our laboratory engineers encounter these distinctions every week, and they directly affect how we design test programs for each product category.

Why Stationary Lithium Batteries Require Special Attention

Stationary lithium batteries differ fundamentally from the portable batteries powering smartphones and laptops. Our testing laboratory evaluates both categories daily on a daily basis, and the distinctions matter enormously for compliance:

  • Scale and energy density: A stationary battery rack for a telecom base station can store 50–500 kWh, compared to 10–50 Wh in a typical smartphone battery. The energy density of lithium-ion chemistry means that a single thermal event in a stationary system can release orders of magnitude more energy.
  • Continuous operation: Unlike portable batteries that users carry and monitor, stationary systems operate unattended for years. They must withstand temperature fluctuations, grid instability, and cycling stress without human intervention.
  • Infrastructure dependency: When a telecom base station battery fails, it doesn’t just inconvenience one person — it can take down cellular coverage for thousands of users across a region.

Because the failure modes of stationary batteries carry such significant consequences, ANATEL and Brazilian technical committees have progressively tightened the safety standards that apply to these products. Manufacturers who treat stationary battery certification as a simple extension of portable battery testing will find their applications rejected.

Our testing protocols are built around the requirements of this standard, and we’ve refined our approach through hundreds of completed evaluations.

IEC 62619: The Core Safety Standard for Industrial Lithium Batteries

The primary international standard governing safety requirements for secondary lithium cells and batteries in industrial applications is IEC 62619:2022. Our engineering team designs test programs around this standard as the baseline for evaluating stationary battery safety, and it is our standard most frequently referenced in ANATEL certification requirements for this product category.

IEC 62619:2022 covers the following critical test categories:

Test Category Specific Tests What It Evaluates
Electrical Safety Overcharge, over-discharge, external short circuit Battery behavior when operated outside normal voltage/current parameters
Thermal Safety Thermal abuse, thermal runaway propagation Whether a single cell failure cascades to adjacent cells
Mechanical Safety Crush, impact, vibration, drop Structural integrity under physical stress
Environmental Temperature cycling, low pressure (altitude simulation) Performance across operating conditions
Fault Conditions Single cell failure, internal short circuit simulation System-level response to component-level failures

One of the most significant updates in IEC 62619:2022 compared to the earlier 2017 edition is the strengthened requirement for thermal runaway propagation assessment. The standard now requires manufacturers to demonstrate that their battery management system (BMS) can detect and isolate a thermal event in a single cell before it propagates to neighboring cells. Because thermal runaway in a multi-cell stationary battery rack can escalate to a catastrophic event within seconds, this test is arguably the single most important evaluation for stationary lithium battery safety.

Our technical team evaluates stationary battery systems against this full matrix of complementary standards to ensure nothing falls through the cracks.

Additional Standards That Apply to Stationary Battery Systems

While IEC 62619 addresses cell and module-level safety, stationary battery systems typically require compliance with additional standards that cover the complete energy storage system. Our laboratory testing scope at RTS covers evaluation against these complementary standards:

IEC 63007 — Secondary Lithium-Ion Cells and Batteries for Stationary Applications

This standard specifically addresses stationary lithium battery applications, including telecom backup power, UPS systems, and grid-connected energy storage. IEC 63007 builds on the foundation of IEC 62619 but adds requirements specific to stationary deployment scenarios, such as:

  • Long-term cycling performance verification (typically 1,000+ cycles at specified depth of discharge)
  • Float charge stability assessment over extended periods
  • Capacity retention requirements after accelerated aging

UN 38.3 — Transport Testing for Lithium Batteries

Before your stationary battery products can even reach Brazil, they must pass UN 38.3 transport safety testing. This is a global requirement under the UN Recommendations on the Transport of Dangerous Goods. Our accredited lab performs UN 38.3 testing as a standard part of our battery certification service, and the eight test items include altitude simulation, thermal cycling, vibration, shock, external short circuit, impact/crush, overcharge, and forced discharge.

IEC 62040 — Uninterruptible Power Systems

For stationary batteries integrated into UPS installations, IEC 62040 series standards apply at the system level. This standard addresses the interaction between the battery, our power electronics, and the load — a dimension that cell-level testing alone does not capture.

Our certification support team has walked manufacturers through this exact sequence dozens of times, and each step carries specific requirements that can delay your timeline if not handled correctly.

Step-by-Step: The ANATEL Certification Process for Stationary Batteries

Based on our experience guiding manufacturers through ANATEL certification, our process follows these stages:

Step 1: Product Classification and Scope Determination. Our certification team first confirms whether your stationary battery product falls within ANATEL’s compulsory certification scope. Products used in telecom infrastructure, broadband networks, and related critical systems almost certainly do.

Step 2: Pre-Compliance Testing.Before submitting to an OCD, we recommend running our full IEC 62619 test suite in our laboratory. This allows manufacturers to identify and address failures in a controlled environment, rather than risking a formal rejection from the OCD. Our battery testing capabilities cover electrical testing (overcharge, over-discharge, short circuit), Performance Testing (capacity, internal resistance), mechanical testing (impact, crush, vibration), environmental simulation (thermal shock, temperature cycling, low pressure), and fault testing (single fault conditions).

Step 3: OCD Selection and Application. Brazil has several ANATEL-designated OCDs. The manufacturer submits test reports, product documentation, and quality management system evidence to our chosen OCD. We actively help our clients prepare our complete documentation package.

Step 4: OCD Evaluation. The OCD reviews our test reports and may request additional testing or clarification. If the product meets all requirements, the OCD issues a conformity certificate.

Step 5: ANATEL Homologation. With the OCD conformity certificate in hand, the manufacturer applies to ANATEL for homologation. Once granted, our product receives an ANATEL homologation number and can be legally sold and operated in Brazil.

Timeline Note: Based on our experience with similar certification pathways, our typical process from initial testing to homologation typically takes 3–6 months. For CB certification of lithium batteries under IEC 62133, our lab delivers test reports in approximately 15 working days, but our OCD evaluation and ANATEL homologation stages add additional time. We recommend starting the process at least 8 months before your target market entry date.

Our engineers consider thermal runaway the single most consequential test in the entire stationary battery evaluation program.

Thermal Runaway Prevention: The Make-or-Break Requirement

If there is one area where our engineers see manufacturers fail most frequently in ANATEL-related testing, it is thermal runaway propagation. Our testing team has thoroughly evaluated stationary battery systems from manufacturers across Asia, Europe, and North America, and the thermal runaway test consistently separates well-designed products from those that need significant re-engineering.

The core requirement is this: when a single cell in a multi-cell battery module enters thermal runaway (achieves self-sustaining exothermic decomposition), the system must demonstrate one of the following outcomes:

  1. Containment: The thermal event does not propagate to adjacent cells within a specified time window (typically 24 hours), or
  2. Controlled venting: The system safely vents flammable gases without ignition, or
  3. System shutdown: The BMS detects the event and isolates the affected cell/module before propagation occurs

Because the consequences of thermal runaway propagation in a stationary battery installation can include fire, toxic gas release, and infrastructure damage, this test carries disproportionate weight in our certification decision. Manufacturers who invest in robust cell-level safety (such as ceramic-coated separators and current interrupt devices) combined with sophisticated BMS algorithms consistently achieve better outcomes.

Our experience across hundreds of battery certification projects has given us a clear picture of where manufacturers stumble most often.

Common Pitfalls We See in ANATEL Battery Certification

Our team has helped manufacturers recover from certification failures, and the same issues recur across different product designs:

  • Inadequate BMS documentation: ANATEL’s OCDs require detailed evidence of our battery management system’s protective functions. Manufacturers who submit only a functional description without oscilloscope captures, timing diagrams, and threshold specifications face delays.
  • Test sample inconsistency: The samples submitted for OCD testing must be identical to production units. We have encountered cases in our practice where manufacturers submitted hand-built prototypes that differed from production models in cell chemistry, BMS firmware, or enclosure materials.
  • Missing Portuguese-language documentation: All user manuals, safety instructions, and labeling for products sold in Brazil must be in Portuguese. This is a common oversight for manufacturers accustomed to English-only documentation.
  • Ignoring INMETRO requirements: In addition to ANATEL, some stationary battery applications may also fall under INMETRO (Brazil’s National Institute of Metrology) requirements, particularly for batteries used in consumer-facing energy storage systems.

How Our Testing Laboratory Supports Your ANATEL Compliance Journey

At RTS (Zhejiang RTS Test Co., Ltd.), we provide one-stop battery testing and certification services that cover our full scope of tests required for ANATEL compliance. Our accredited laboratory capabilities include:

  • Electrical testing: Low-rate charging, overcharge, over-discharge evaluations against IEC 62619 requirements
  • Performance testing: Capacity verification, DC/AC internal resistance measurement
  • Mechanical testing: Impact, shock/crush, and vibration testing per IEC 62619 and UN 38.3 protocols
  • Environmental simulation: Low-pressure (altitude) testing, thermal shock, and temperature cycling
  • Fault testing: Short-circuit and single-fault condition evaluation

We maintain internationally recognized accreditations and our testing methods are consistent across our four office locations in Yiwu (Zhejiang headquarters), Ningbo, Hong Kong, and Barcelona, Spain. Our CB certification reports for lithium batteries are delivered within 15 working days under standard conditions, and our UL 1642 testing program completes in approximately 40 working days.

Because we test batteries against our standards that ANATEL OCDs reference, our pre-compliance testing gives manufacturers a reliable prediction of their OCD evaluation outcome — before they commit to our formal certification process.

Our dedicated market intelligence team tracks regulatory developments across all major markets, and Brazil’s trajectory is particularly noteworthy for battery manufacturers.

Preparing for the October 2026 Compliance Deadline

Brazil’s regulatory environment for lithium batteries continues to evolve as the country expands its telecom infrastructure and renewable energy capacity. Manufacturers targeting our target Brazilian market should be aware of several developments:

  • Tightening safety requirements: ANATEL’s technical requirements are progressively incorporating more stringent safety evaluations, particularly around thermal management and propagation resistance.
  • Increased scrutiny of Chinese-manufactured batteries: As the volume of lithium battery imports from China grows, Brazilian authorities are paying closer attention to conformity documentation and test report authenticity.
  • Alignment with international standards: Brazil is moving toward greater alignment with IEC and UN standards, which means that manufacturers who already test to these international benchmarks have a compliance head start.

For manufacturers planning to enter or expand in the Brazilian market by October 2026, we recommend our clients follow this timeline:

Phase Timeline Key Actions
Pre-compliance testing Now – Month 2 Submit samples for full IEC 62619 + UN 38.3 testing at an accredited lab
Design remediation Month 2 – Month 3 Address any test failures; redesign BMS, cell configuration, or enclosure as needed
Retesting and OCD submission Month 3 – Month 5 Retest failed items; submit complete documentation package to OCD
OCD evaluation Month 5 – Month 7 Respond to OCD queries; provide additional evidence if requested
ANATEL homologation Month 7 – Month 8 Apply for and receive ANATEL homologation

Important: This timeline assumes no major test failures. If thermal runaway propagation testing reveals design issues, the remediation and retesting cycle can add 2–3 months. Starting early is our single most effective risk mitigation strategy.

Our experienced support team fields these questions regularly from manufacturers exploring the Brazilian market for the first time.

Frequently Asked Questions

Q1: Does ANATEL certification apply to all stationary lithium batteries, or only those used in telecom?

ANATEL’s jurisdiction covers products used in telecommunications infrastructure. If your stationary battery is designed for or deployed in telecom base stations, network equipment rooms, or broadband infrastructure, ANATEL certification is mandatory. Batteries used exclusively in non-telecom applications (such as residential solar storage with no telecom component) may fall under different regulatory bodies like INMETRO. However, in practice, many stationary battery systems serve dual purposes, and we recommend consulting with a certification body to determine our exact scope.

Q2: Can we use existing IEC 62619 test reports from another country for ANATEL certification?

ANATEL OCDs generally accept test reports from ILAC-accredited laboratories, regardless of the country where the testing was performed. However, the test reports must be current (typically issued within the past 2–3 years), the tested samples must match the production units being submitted, and the reports must cover our complete IEC 62619 test suite. Our technical team reviews existing reports and identifies any gaps that need supplementary testing before OCD submission.

Q3: What is the difference between IEC 62619 and IEC 62133 for battery certification?

IEC 62619 targets industrial and stationary applications — battery racks for telecom, UPS systems, and energy storage. IEC 62133 targets portable applications — batteries in consumer electronics, power tools, and mobile devices. The test methods differ significantly: IEC 62619 includes thermal runaway propagation testing at the module level, while IEC 62133 focuses on cell-level safety. For stationary battery certification in Brazil, IEC 62619 is our applicable standard.

Q4: How long does ANATEL homologation remain valid?

ANATEL homologation certificates have a defined validity period, typically 2 years for most product categories. Manufacturers must apply for renewal before expiration to maintain market authorization. Changes to the product design, cell supplier, or BMS firmware may require a new certification cycle rather than a simple renewal.

Q5: What happens if we sell stationary batteries in Brazil without ANATEL homologation?

Selling or operating non-homologated telecommunications equipment in Brazil is illegal under ANATEL regulations. Penalties can include product seizure, fines, and prohibition from the Brazilian market. Brazilian telecom operators are also required to use only homologated equipment, so even B2B sales channels enforce compliance.

Q6: Does RTS provide end-to-end ANATEL certification support, or only testing?

We provide comprehensive support from pre-compliance testing through OCD submission preparation. Our services include full IEC 62619 testing, UN 38.3 transport testing, documentation preparation, and technical consultation on design improvements for test failures. We actively coordinate with ANATEL-designated OCDs on behalf of our clients, though our final homologation application is submitted directly by the manufacturer or their authorized representative in Brazil.

Q7: What are our most commonly observed reasons stationary lithium batteries fail ANATEL-related testing?

In our testing experience, our three most common failure modes are: (1) thermal runaway propagation — our BMS fails to detect or isolate a single-cell thermal event before it spreads, (2) overcharge protection inadequacy — our protection circuit does not reliably disconnect at the specified overcharge voltage threshold, and (3) enclosure integrity under mechanical stress — our battery housing cracks or deforms during crush or impact testing, exposing cells. Manufacturers who address these three areas proactively have a significantly higher first-pass success rate.

LH

Lara Hong

Business Development Manager at Zhejiang RTS Test Co., Ltd.

A pioneer in third-party inspection, testing, and certification consulting services for global trade and e-commerce. Specialized in helping manufacturers and exporters navigate compliance requirements, product testing standards, and market access regulations. Dedicated to delivering trust for quality life — bridging the gap between producers and global buyers through accurate, fair, and standardized testing services.

LinkedIn

Ready to Start Your ANATEL Battery Certification?

Our testing team is here to guide you through every step — from pre-compliance testing to OCD submission.

Contact Us Today